Fluke 787B ProcessMeter, 1000 V
mA loop calibrators
⃀ 5,718.81/Each
(ex VAT)
⃀ 6,576.63/Each
(inc VAT)
Combines the capabilities of a safety-rated digital multimeter and mA loop calibrator into one tool, this process meter is ideal for troubleshooting and calibrating current loop applications due to its ability to measure, source, and simulate mA. Additionally, it is Fluke Connect compatible when paired with the FC connector.
| Stock No. | FLK4777186 |
|---|---|
| Manufacturer | Fluke |
| Part No. | 787B |
| Supplied/Stocked By | FLUKE |
Fluke 787B Offers
Features
- 20 mA DC current source/measure/simulate
- Simultaneous mA and % of scale readout
- Digital multimeter designed to meet 1000 V IEC 61010 CAT III and 600 V CAT IV standards
- Fluke Connect compatibility for wireless data logging
- Precision 1000 V, 440 mA True RMS digital multimeter
- Frequency measurement to 20 kHz
- Min/max/average/hold/relative modes
- Diode test and continuity beeper
- Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Externally accessible battery for easy battery changes
Applications
- Troubleshooting
- Calibrating current loop
What's included with the Fluke 787B
- ProcessMeter
- Test Lead Set
- Aligator Clips
- 4 x Alkaline Batteries (Installed)
- Quick Reference Guide
| V DC | |
|---|---|
| Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| Best Accuracy (% of Reading + LSD) | 0.1% + 1 |
| V AC (True RMS) | |
| Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
| Best Accuracy (% of Reading + LSD) | 0.7% + 2 |
| mA DC | |
| Range and Resolution | 30.000 mA |
| Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
| mA DC | |
| Range and Resolution | 30.000 mA |
| Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
| A DC | |
| Range and Resolution | 1.000 A (0.440 A continuous) |
| Best Accuracy (% of Reading + LSD) | 0.2% + 2 |
| A AC | |
| Range and Resolution | 1.000 A (0.440 A continuous) |
| Best Accuracy (% of Reading + LSD) | 1% + 2 |
| Resistance | |
| Range and Resolution | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M |
| Best Accuracy (% of Reading + LSD) | 0.2% + 1 |
| Frequency (0.5 Hz to 20 kHz) | |
| Range and Resolution | 199.99 Hz, 1999.9 Hz, 19.999 kHz |
| Best Accuracy (% of Reading + LSD) | 0.005% + 1 |
| Diode Test | |
| Range and Resolution | 2.000 V (shows diode voltage drop) |
| Best Accuracy (% of Reading + LSD) | 2% + 1 |
| Continuity | |
| Range and Resolution | Beeps for resistance <approx. 100 Ω |
| DC Current Output (Internal Battery Operation) | |
| Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
| Drive Capability | 24 V compliance or, 1,200 ohms, at 20 mA |
| Accuracy (% of Span) | 0.05% |
| DC Current Simulate (Ext. 15 to 48 V Loop Supply) | |
| Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
| Drive Capability | 1000 ohms, at 20 mA |
| Accuracy (% of Span) | 0.05% |
| Current Adjustment Modes | |
| Manual | Coarse, Fine, 25% and 100% step |
| Automatic | Slow Ramp, Fast Ramp, 25% step |
| General Specifications | |
| Maximum Voltage Applied Between any Jack and Earth Ground | 1000 V RMS |
| Storage Temperature | -40 to 140°F (-40 to 60°C) |
| Operating Temperature | -4 to 131°F (-20 to 55°C) |
| Temperature Coefficient | 0.05 x (specified accuracy) per °C (for temperatures <18°C or >28°C) |
| Relative Humidity | 95% up to 86°F (30°C)75% up to 104°F (40°C)45% up to 122°F (50°C)35% up to 131°F (55°C) |
| Vibration | Random, 2 g, 5 to 500 Hz |
| Shock | 3.3' (1 m) drop test |
| Battery | 4 x AA Alkaline batteries |
| Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
| Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
| Dimensions | 1.97 x 3.94 x 8" (50 x 100 x 203 mm) |
| Weight | 1.3 lbs (600 g) |
Parts List